Sipariş No : Y-0028B

Inductance Box

Y-0028B



The inductances are coiled on ferrite nucleus with a high Q factor. Supply Voltage is depends to used frequency in high ratio, therefore to don’t let the inductance over heating and satisfaction it is necessary to beware the applied voltage. The inductance can be adjusted via rotary switch and each switch has 10 status. 6 different switches are used on the box. The box has 4 mm isolated output sockets, metal case and grounded front panel.


Tender Specifications

INDUCTANCE BOX

The inductances should be coiled on ferrite nucleus with a high Q factor. Supply Voltage is depends to used frequency in high ratio, therefore to don’t let the inductance over heating and satisfaction it should be necessary to beware the applied voltage. The inductance should be adjusted via rotary switch and each switch should have 10 status. 6 different switches should be used on the box. The box should have 4 mm isolated output sockets, metal case and should be grounded front panel.

TECHNICAL SPECIFICATIONS
Inductance Measurement Range    :    1µH…1Henry
Accuracy            :    ± 5 %
Size                :     Min. 280 x 155 x 55 – 85mm
Weight                :    MNax. 1.60 Kg
Rotary switch            :    Min. 6 pieces with 10 status

APPLICATION LIMITS
X 1 µH            :    1 µH     –    9 µH
X 10 µH            :    10 µH     –    90 µH
X 100 µH        :    100 µH     –    900 µH
X 1 mH            :    1 mH     –    9 mH
X 10 mH            :    10 mH     –    90 mH
X 100 mH        :    100 mH     –    900 mH