Sipariş No : Y-0082

PID Control Training Set

Panel Type Main Unit



Datasheet  Tender Specifications

PID Control Training set is designed to provide skills in a basic idea and controllers and to teach the basic principles by applying different signals on PID. The working possibility in 2 modes with PID control is provided.These are;ON / OFF control mode and continuity mode.

P-control mode, I-control mode, D-control mode, PI-control mode, PD-control mode and PID control mode can be operated independently and can be used with different combinations in open and closed loop on the set. The difference between different modes of controllers can be observed clearly. The impact of PID training set can be seen on first instruction system and second instruction system in the open and closed loop system applied on the set.

The Square Wave and Triangle Wave generators, constant power supply and Audio generator are placed on the PID Control Training Set to help the experiments.
 
• Proportional, integral and differential functions can be controlled on the same board. (P, I, D, PI, PD, PID adjustable)
• ON/OFF controller
• Square and triangle wave with variable frequency for PID test
• Variable DC Power Supply for setting point
• Error detector
• First order system and third order system
• 3½ digit indicator for DC measurement
• Audio generator
• Test point for observation and signal measurement
• Dead zone and disturbances

Technical Specifications :

Supply Voltage                                                                             : 220V AC / 50 - 60 Hz / ±10 %
DC Symmetric Fixed Power Supply                                          : +12V - 0 - +12V
Reference Generator - 1                                                             : - 10V - +10V
Reference Generator - 2                                                             : - 6V - 0 - +6V
Function Generator                                                                     : Triangle, Square
                 Amplitude                                                                    : 0 – 8Vpp
                 Frequency                                                                    : 0 – 156Hz
Voltmeter                                                                                      : 3½ Dijit, Elektronic Protected
Proportional Band                                                                       : 5%...55%
Integrator                                                                                      : 10m/sec...110 m/sec
Differantial                                                                                   : 1 ms...11ms
ON / OFF Controller                                                                    : ON: 12V, OFF : ( - 12V)
Power Consumption                                                                  : 1,6VA

 


Tender Specifications

 

PID CONTROL TRAINING SET

PID control training set should be designed to provide skills in a basic idea and controllers and to teach the basic principles by applying different signals on PID. The working possibility in 2 modes with PID control should provided. These shall be;    ON / OFF control mode and continuity mode.

P-control mode, I-control mode, D-control mode, PI-control mode, PD-control mode and PID control mode should be operated independently and shall be used with different combinations in open and closed loop on the set. The difference between different modes of controllers should be observed clearly. The impact of PID training set should be seen on first instruction system and second instruction system in the open and closed loop system applied on the set.

The Square Wave and Triangle Wave generators, constant power supply and Audio generator should be placed on the PID control training set to help the experiments.

• Proportional, integral and differential functions should be controlled on the same board.  
(P, I, D, PI, PD, PID adjustable)
• ON/OFF controller
• Square and triangle wave with variable frequency for PID test
• Variable DC Power Supply for setting point
• Error detector
• First order system and third order system
• 3½ digit indicator for DC measurement
• Audio generator
• Test point for observation and signal measurement
• Dead zone and disturbances

TECHNICAL SPECIFICATIONS

Supply Voltage            : 220V AC / 50 - 60 Hz / ±10 %
DC Power Supply        : Voltmeter with 3½ Digit LED Electronics protection
Variable DC reference Voltage - 1    :  - 6 V to +6 V
Variable DC reference Voltage - 2    : - 10 V to +10 V
Function Generator Outputs     : Triangle, Square, Amplitude : 0 – 8 Vpp, Frequency: 0 – 156 Hz
Proportional band         : 5%...55%
Integrator             : 10m/sec...110 m/sc
Differential             : 1 msn...11 msn
ON / OFF Controller        : ON : 10 V, OFF : ( - 10 V)
Power Consumption         : 1,6 VA
Connection leads 2 mm sockets
Power cable / length        : IEC / Min 2 meters
Size / weight             : Min 340 x 240 x 105mm – Max 1,35kg

SYSTEM SHALL INCLUDE

2mm Connection Leads             
Power Cable                 : Min 1 Pc, IEC, 2m
Experiment Book         : 1 Pc





Download Product's Tender Specifications

Videos

Documents (Catalogue-Brochure-Manual)


Related Products


0