Sipariş No : Y-0049

Fire Alarm Systems Application Sets

Y-0049



Fire Alarm Systems Application Sets has 2 subtitles as follows

  • Y-0049/A Conventional Fire Alarm System Application Set
  • Y-0049/B Addressable Fire Alarm System Application Set 

Common specifications of modules which are used in Fire Alarm Systems Application Sets are follows;

  • 30cm x 18cm insulator panels
  • 25cm x 18cm x 12,5cm plastic box
  • Circuit diagram on panel
  • All inputs and outputs are double isolated 4mm banana plug

Y-007 Laboratory Desk and Y-008 Module Storage Cupboard can be selected as an optional with application sets. 

Modules can be used after having the desired energy and setting up the connections on Y-007 Laboratory Desk with AC / DC Energy Unit. 

Y-007 Laboratory Desk is designed with required monophase AC / DC energy units. Laboratory Desk is made of aluminum and has rubber leg. Moreover, working surface is made of laminate and has 2 rows of railed system.


Tender Specifications

CONVENTIONAL FIRE ALARM SYSTEMS APPLICATION SET

SET SHOULD INCLUDE FOLLOWING APPLICATION MODULES
•    Conventional Fire Alarm Controller Module
•    Combined Heat Speed and Fixed Heat Detector Module
•    Optical Smoke Detector Module
•    Relayed Optical Smoke Detector Module
•    Relayed Heat Detector Module
•    Relayed Gas Detector (LPG - LNG) Module
•    Electrical Alarm Module
•    Flasher Alarm Module
•    Fire Alarm Button Module
•    Fire Alarm Button (Test) Module
•    Warning Light Lamp Module (min. 2 Pcs)
•    Battery Module (min. 2 Pcs)

TECHNICAL SPECIFICATIONS
•    Min. 30cm x 18cm insulator panels
•    Min. 25cm x 18cm x 12cm metal box
•    Circuit diagram should be on panel
•    All inputs and outputs shall double isolated with 4mm banana plug

SET SHOULD INCLUDE FOLLOWING ITEMS
•    Connection Cables; Isolated probe cable suitable for 4mm banana plug
•    Connection Cables Suitable for IEC; One side male IEC and the Other side female IEC
•    Fire Alarm Systems Application Sets experiment book

ADDRESSABLE FIRE ALARM SYSTEMS APPLICATION SET

SET SHOULD INCLUDE FOLLOWING APPLICATION MODULES
•    Addressable Fire Alarm Controller Module
•    Addressable Heat Detector Module
•    Addressable Optical Smoke Detector Module
•    Addressable Gas Detector (LPG - LNG)  Module
•    Addressable Fire Alarm Button Module
•    Flasher Alarm Module
•    Addressable Input Module
•    Addressable Output  Module
•    Warning Light Placed Lamp Module (Min. 2 Pcs)  
•    Addressable Module
•    Battery Module (Min. 2 Pcs)

TECHNICAL SPECIFICATIONS
•    Min. 30cm x 18cm insulator panels
•    Min. 25cm x 18cm x 12cm metal box
•    Circuit diagram should be on panel
•    All inputs and outputs shall double isolated with 4mm banana plug

SET SHOULD INCLUDE FOLLOWING ITEMS
•    Connection Cables; Isolated probe cable suitable for 4mm banana plug
•    Connection Cables Suitable for IEC; One side male IEC and the Other side female IEC
•    Fire Alarm Systems Application Sets experiment book